Friday, April 16, 2010

Manoj Kumar sah

Manoj Kumar Sah
 Research and Development
Siemens Information System Limited
+918970493311
manojsah.mail@gmail.com





Currently working As a  associate consultant in
  research and development of
Siemens information system limited
 INDIA

 Dec-2009-till the Date: M/S Kaiga Generating station(KGS), NPCIL
KGS Unit 3&4, Nuclear Power Corporation India limited.
Responsibility: Project Engineer-Design & Commissioning.
Design, selection, verification and modification of single line diagram, control schemes and cables schedules. Relay coordination studies, short circuit studies, load studies of a 16.5KV/220Kv/220Kv substation. All type of IEC tests, simulation and Commissioning of same switchyard and control substation including Power Transformer, circuit Breaker, and Siemens Hi-burden electromagnetic relays like CDG,CAD,VAG, Power relays, frequency relays, etc.

 Sep-2009-4th Dec 2009: M/S Schneider Electric, Abu Dhabi
Abu Dhabi Polymers Company Limited (Borouge-2 Project)
Ruwais, Abu Dhabi, UAE
Responsibility: Project Engineer-Design & Commissioning
Preparation of relay coordination study, load studies, short circuit calculation of 11KV and 415V Incoming/Outgoing feeders and testing of Sepam 20, 40, 80 series and latest Outgoing Motor control TeSys T Relays and commissioning of all relays according to the setting values on No-load/load Upgradation of relays firmware and programming of re-acceleration type of motors.

 Mar-2009-Aug-2009: M/S L&T Limited-Panipat.
MSQ UPGRADATION PROJECT.PANIPAT REFINERY
Indian Oil Corporation limited (IOCL).
Responsibility: Project Engineer-Design & Commissioning.
Design, selection and procurement of power transformer, distribution transformer and cables. Verification and modification of single line diagram, control schemes and cables schedules. Relay coordination studies, short circuit studies, load studies of a new 33KV/415v substation. All type of IEC tests, simulation and Commissioning of same new substation including Power Transformer of 31.5MVA, Distribution transformer, circuit Breaker, 6.6KV Bus Bar, Motors, and Siemens Siprotec Relays and numbers LT feeders, circuit breaker of L&T.

 Dec.2008-Mar-2009: M/S L&T Limited-Panipat.
PANIPAT NAFTA CRACKER PROJECT (PNCP).PANIPAT REFINERY
Indian Oil Corporation limited (IOCL).
Responsibility: Project Engineer-Design & Commissioning.
Design, selection and procurement of power transformer, distribution transformer and cables. Verification and modification of single line diagram, control schemes and cables schedules. Relay coordination studies, short circuit studies, and load studies of a new 33KV/11KV / 415v substation. All type of IEC tests, simulation and Commissioning of same new substation including Power Transformer of 31.5MVA, Distribution transformer, circuit Breaker, 6.6KV Bus Bar, Motors, and Siemens Siprotec Relays and numbers LT feeders, circuit breaker of L&T.

 May.2008-Dec.2008: M/S ABB Limited –New-Delhi.
DELHI METRO CORPORATION LIMITED (DMRC Project)
Yammuna Bank & Yammuna Bank Depot Station.
Responsibility: Project Engineer-Commissioning.
Preparation of relay coordination study of 33KV/415V, Incoming/Outgoing feeders and testing of ABB REM series and SPAJ 140C and commissioning of Transformer, Circuit Breaker and relays according to the setting values on No-load/load.

 Jul.2007 -Mar.2008: Areva T&D/ L&T Limited.
Commissioning of 2 x 5 MW Generator Static & Protection relays.
TATA Steels Ltd, Tatanagar, Jharkhand
Responsibility: Project Engineer-Commissioning.
Preparation of relay coordination study and setting values for the Generator protection relays Testing, Simulation and commissioning the generator on No-load.





SERVICE-: System Design, Testing and Commissioning Engineer with Managerial Grade, R&D Application & testing support.


 A First Class Electrical and Electronics Engineering Graduate with 3 years of experience as a Electrical Commissioning Engineer.

 Design, Calculation and Preparation of Relays Coordination, Short Circuit Fault current, and methods of testing numerical Protections and Enabling.

 Commissioning of protection systems with station automation system and electromagnetic relays.

 Configuration of Numerical Protection terminals as per system requirement.

 Customer complaint resolution and fault analysis, Training to customers on various Protection.

 Special/Diagnostic test like Flux Frequency Test(FFT/FRA), Thermography(TI), Motor Current Signature Analysis(MCSA), RLA of Electrical Equipments, AC Very Low Frequency test, Partial Discharge test, Tan Delta AC & DC HI- POT, Dielectric Losses.

 Commissioning of ABB (REX Series REM Series), SIEMENS Siprotec (7SJ series, 7UT series, and 7SD series), SCHNEIDER (Sepam series & TeSys), Areva (P-521, P-221), Mi-com, and Alstom Relays.

 Commissioning of CAG, CDG, VAG, SPAM, VDG, VAG, VAA, CTUM, CCUM and more electromagnetic types relays.

 Various type of protection relays like Generator protection, Cable Differential, Line protection, Transformer Protection, Transformer Differential protection with pilot wire, Motor Protection, Bus Bar protection, stability & sensitivity, and Synchronization, Feeder Differential, Motor & Generator Differential.

 Feeder Protection & Control terminals: REF 543-5, REX 521, REJ 523, REJ 525, Comb flex relays & REC 670.

 Cable/line Differential relay: Areva (P-521, P-221), Mi-com, and Alstom.

 Configuration Tools: Digsi, Omicron, Isa, power suite, SFT2841, Micom Studio, PMC600, Simulator software and more.

 Tendering and Client Management in areas of Power system.

 Searching tender on internet and developing business according to the market studies and managing quick solutions and service to the new and existing client.

 Updating company profiles and making presentations to the client and top executive of company to implement new business.






PRE-COMMISSIONING AND COMMISSIONING OF:

 Pre-Commissioning and Commissioning of new 220KV overhead and underground distribution network & substations, and commissioning of 33KV Gas Insulated System (GIS), 66KV AIS along with all protection System.

 Pre-Commissioning of Electrical Equipments like Generators, Under ground Cables, Power Transformers, Reactors, Motors (HT & LT), Alternator, Distribution transformers, Current Transformer(400KV), potential transformers, Electrical switchgear (HT & LT).

 Commissioning of numerical protection relays and electromagnetic relays.

 Calibration, testing and commissioning of electrical protection relays such as o/c, instantaneous o/c relays, time delayed o/c relays, definite time relays, directional o/c relays, differential relays and reverse power relays.

 Various types of system electrical equipments like isolators, capacitor banks, reactors, surge arrestor’s, breakers, Battery Charger, UPS, Battery bank.

 Calibration and error adjustment of energy meters, power factor meters, ammeters, voltmeters, kilowatt meters, including digital meters.

 Excellent grasping capability and understanding the concepts clearly
 Ability to adjust to the situation.
 Ability to work under pressure and deadline situations.
 Sense of Responsibility and a smart hard worker.
 A Self motivated team player, with excellent confidence & commitment


 Interested to learn more about new technologies.

 Like to watch and play football.

 Interested in cooking and eating.




Bachelor of Engineering (Electrical & Electronics) in June 2007 from Bapuji Institute of Engineering and Technology, Davangere Bangalore, INDIA.

Higher Secondary School in July 2003 from Siddharth Residential School Vijayawada, INDIA

Secondary School in June 2001 from Gautam English Secondary School, Birgunj, NEPAL



Name : Manoj Kumar Sah

Birth : 26.01.1985

Marital Status : Single

Passport Number : 4062687

1 comment:

  1. You done a great job admim.In power system networks, protection has to be designed such that protective relays isolate the faulted portion of the network, to prevent equipment damage, injury to operators and to ensure minimum system disruption enabling continuity of service to healthy portion of the network. If you want to know more about the Relay Coordination, Please Visit, Relay Coordination

    ReplyDelete